Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device

Product Details
Customization: Available
After-sales Service: Provided
Warranty: 18 Months
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
to see all verified strength labels (11)
  • Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
  • Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
  • Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
  • Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
  • Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
  • Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Find Similar Products

Basic Info.

Model NO.
PGD
Type
Centrifuge
Separation Mode
Filter Type
Operating Type
Intermittent Type
Installation
Vertical
Condition
New
Model No.
Pgd
Material
Stainless Steel, Titanium Alloy,Halar
Voltage
200V-415V
Discharge
Automatic Bottom Discharge Bag Pulling
Cover Opening Type
Big Hinged Cover
Control
PLC Control
Shock Absorbing System
Liquid Damping Shock Absober
Braking System
Dynamic Braking
Explosion-Proof
Yes
GMP
Optional
CIP
Optional
Motor Drive
Frequency Inverter
Transport Package
Standard with Wooden Pallet and Poly Film Wrapping
Origin
China
Production Capacity
500 Sets/Year

Product Description


PGD Vertical Scraper Bottom Discharge Automatic Centrifuge With Bag Pulling Action
Product introduction
PGD1250N series centrifuge is a new type of centrifuge that can completely remove the residual cake.This series centrifuge retains such primary functions offered in the LGZ series as the solid-liquid separtion and scraper discharge,and adds such function as to remove the residual solid cake by shaking filter cloth with the removal rate higher the 99%.PGD series avoids crossing and mixing of different batches of separated products,and also eliminates the effects of the residual solid cake on the basket wall.it is mainly used in the solid-liquid separation process in such industries as pharmacy,food,gourmet powder and chemistry.
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device

  
Operating principle
Material to be separated enters into the basket of the centrifuge that is rotating at high speed through a feeding pipe,and under action of the centrifugal force,the material passes through the filter cloth for filtration.Then the liquid phase discharges through the discharge pipeline,while the solid phase is retained in the basket.Feeding stops once the basket is filled with the material,then wash the solid cake,and discharge the washing liquid through filtration.The centrifuge continues to rotate to spin-dry the solid cake.After the solid meets the requirements for separation,the centrifuge reduces its speed,and removes the cake by means of the scraper,then discharges the cake out of the centrifuge.The centrifuge further reduces its speed so that the pneumatic shaking bag device moves reciprocally to shake off the residual solid cake,thus completely eliminating the solid cake

Operating process
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device

Main features
  1. Liquid damping vibration isolator, No foundation for installation , the operation and maintenance are more convenient
  2. Big hinged cover construction form,easier maintenance and cleaning;
  3. Arch cover design with sufficient strength and rigidity can effectively prevent the influence of cover deformation on sealing performance;
  4. Movable liquid blocking plate design,convenient and quick to remove and replace the bag-shaking;
  5. The integrated design of main shaft and lifting cylinder makes the transmission structure more compact and reasonable;
  6. Humanization design: No foundation for installation, broad working platform, various warning and notice signs,etc.;
  7. The automatic bag-shaking device can remove the residual cake  completely,so as to prevent crossing contamination between batches of materials;
  8. Safety protection device: over vibration protection, over current protection, overload protection,solid cake thickness detection,cover opening protection,speed monitoring,interlock protection,Nitrogen protection, etc. ,ensure the safety of the machine;
Technical Parameters
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Nitrogen protection system 
    Nitrogen protection system is an option for customers when the machine working in flammable or explosive places,which can improve the safety of centrifuge used in these occasions,so as to reduce the use risk.
    Fill a certain pressure of nitrogen into the closed centrifuge chamber to replace the air in the chamber, and reduce the oxygen content of the centrifuge to the safe range, and then keep the micro positive pressure in the centrifuge chamber all the time to ensure that the oxygen content in the centrifuge is within the safe range, so as to improve the safety of the centrifuge.
    
Before nitrogen filling, confirm whether the pressure, flow and nitrogen concentration of nitrogen source meet the use requirements:
    1. Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
      Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
      Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Name Parameter Influence
Nitrogen filling pipe diameter D16 The smaller the nitrogen filling pipe diameter is, the longer the replacement time will be
Nitrogen source pressure 2-3bar Slightly affect nitrogen filling replacement time
Nitrogen charging pressure (working condition) 1.5bar Affect nitrogen filling replacement time
Nitrogen flow (standard condition) 0.8-0.9m3/min(Large flow )+0.05m3/min(small flow) Affect nitrogen filling replacement time
Nitrogen consumption of large flow nitrogen filling(standard condition 2.5-3m3 in 3 minutes Affect nitrogen filling replacement time
Nitrogen purity ≥99% The lower the purity of nitrogen, the more times the replacement time of nitrogen filling and the oxygen content of centrifuge meet the requirements (conventional 4% ~ 6%
Under the above conditions, it is found that the replacement time of
 nitrogen filling is about 5 minutes when the oxygen content in the
 centrifuge reaches 5%.
Customer use cases
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
 
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device
Pgd/PLD Vertical Scraper Bottom Discharge Automatic Centrifuge with Bag Pulling Device


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier